1 basic operation – IAI America MSEP User Manual

Page 78

Advertising
background image

3.1 Basic Operation

70

ƔOperation Mode Available in PIO Type

6 types of operation modes (PIO Patterns) are available to select from.

Explained below is the outline. Also, in the table below, provides the relevant air cylinder circuit

for reference.

Operation Pattern

Description

Example for Electric Cylinder

Connection

Example for Air Cylinder

Connection (Reference)

PIO Pattern 0

Single Solenoid System

(Standard Point-to-Point

Movement)

PLC

+24V

Movement Signal

(ST0)

Backward

Position Detection

(LS0)
Forward

Position Detection

(LS1)

Dedicated

Cable

Electric Cylinder

MSEP

R2

R1

B

A

Spring

Solenoid

Air Cylinder

PLC

Movement Signal

(ST0)

P(Air)

Forward

Position Detection

(LS1)

Backward

Position Detection

(LS0)

PIO Pattern 0

Double Solenoid System

(Standard Point-to-Point

Movement)

The actuator

point-to-point movement

is available using the

same control function as

for the air cylinder.

The target position setting

(forward position and

backward position) is

available.

Speed and acceleration

settings in the actuator

movement are available.

The pressing operation is

available.

+24V

PLC

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Backward

Position Detection

(LS0)
Forward

Position Detection

(LS1)

Dedicated

Cable

Electric Cylinder

MSEP

R2

R1

B

A

Solenoid

Solenoid

Air Cylinder

PLC

P(Air)

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Backward

Position Detection

(LS0)
Forward

Position Detection

(LS1)

PIO Pattern 1

Single Solenoid System

(Point-to-Point Movement,

Movement Speed Setting)

+24V

PLC

Movement Signal

(ST0)

Movement Speed

Change Signal

(SPDC)

Backward

Position Detection

(LS0)
Forward

Position Detection

(LS1)

Dedicated

Cable

Electric Cylinder

MSEP

Spring

R2

R1

B

A

Solenoid

Air Cylinder

PLC

P(Air)

Movement Signal

(ST0)

Movement Speed

Change Signal

(SPDC)

Backward

Position Detection

(LS0)
Forward

Position Detection

(LS1)

PIO Pattern 1

Double Solenoid System

(Point-to-Point Movement,

Movement Speed Setting)

The actuator

point-to-point movement

is available using the

same control function as

for the air cylinder.

The movement speed can

be changed while the

actuator is moving if the

movement speed change

signal is input.

The target position setting

(forward position and

backward position) is

available.

Speed and acceleration

settings in the actuator

movement are available.

The pressing operation is

available.

+24V

PLC

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Movement Speed

Change Signal

(SPDC)

Backward

Position Detection

(LS0)

Forward

Position Detection

(LS1)

Dedicated

Cable

Electric Cylinder

MSEP

R2

R1

B

A

Solenoid

Solenoid

Air Cylinder

PLC

P(Air)

Backward Position

Movement Signal

(ST0)

Forward Position

Movement Signal

(ST1)

Movement Speed

Change Signal

(SPDC)

Backward

Position Detection

(LS0)

Forward

Position Detection

(LS1)

Advertising