Chapter 3 Programs

96

(16) The actual stop position may fluctuate approximately ±1 pulse from the target position depending on

the encoder resolution (mm/pulse) of the master axis. Moreover, the current position may exceed the

target position momentarily due to overshoot, etc. Please take the following points into consideration.

z

If you perform synchronous movement by setting “the master axis reaching the specified

synchronization start point” or “execute single cycle only” as the synchronization type, shift the

target position back and forth such that the master axis arrives at (or passes) the synchronization

start/end position without fail.

(Note) If you perform the movement such that the master axis passes the synchronization start

position without fail, try to execute the synchronization start instruction considering the

synchronization type as "immediate" after the movement to the synchronization start

position is completed.

[1] Moving to the direction of synchronization end position after moving from a position between

synchronization start and end positions to the synchronization start position

[2] Moving from a position before synchronization start position to synchronization start position

Synchronization start position

Synchronization end position

Movement 2

Movement 1

Master axis position

Target position

Current position

Synchronization start position

Synchronization end position

Master axis position

Current position

Target position

Movement