11

X-SEL-P/Q Controller (with Extension Motion Control Board)

[1] Extension motion control board

One board is equipped with 8 pulse outputs and 2 pulse inputs.

It is possible to mount up to 2 extension motion control boards on the XSEL-P/Q controller. It

becomes possible to control RC controllers with up to 16 axes of pulse train I/O types.

[2] PIO boards

There are following 3 types of PIO boards with different number of I/O points.

x

Input 32 points/output 16 points

x

Input 16 points/output 32 points

x

Input 48 points/output 48 points

When controlling pulse inputs/outputs, it becomes necessary to connect 4 inputs (5 inputs) and 3 outputs

of a PIO board per axis on the X-SEL side for the connected RC controller. The number of PIO boards

and occupied PIO ports are determined by the number of connected RC controllers.

Direction

X-SEL side

Function

RC controller side

Input

General-purpose input SV (Servo ON status)

PIO connector 2B Red-3

General-purpose input INP (Position complete status)

PIO connector 3B Orange-3

General-purpose input HEND (Home return completion

status)

PIO connector 4B Yellow-3

General-purpose input ALM (Alarm status)

PIO connector 6B Blue-3

General-purpose input RMDS (Operation mode status) PIO connector 8B Gray-3

Output General-purpose output SON (Servo ON command)

PIO connector 5A Green-1

General-purpose output HOME (Home return command) PIO connector 7A Purple-1

General-purpose output RES (Alarm reset)

PIO connector 6A Blue-1

(Note) Operation Status Signal is the signal dedicated for SCON-C, SCON-CA and PCON-CA. There is

no such signal in PCON-PL and ACON-PL.