IAI America XSEL-S User Manual

Page 177

Advertising
background image

Chapter 5 Handling Errors

169

Level

No.

Error name

Description/Action

Movement

cancellation

47C Extension motion control board synchronous

movement axis setting error

There are errors in axis settings for extension motion control

board synchronous movement. When setting the master axis

of synchronous electronic CAM and electronic shaft

synchronous movement is set as a slave axis as well, axis

setting where the correspondence of slave axis to master axis

closes in ring shape is not allowed.

Movement

cancellation

47D Slave driver home return completion signal

OFF error

Home return completion status signal OFF of pulse train driver

(SCON, ACON, PCON, etc.) was detected. Check for cable

disconnection and so on.

Movement

cancellation

47E

Synchronization start error during extension

motion control board input channel counter

clear

It was attempted to start synchronous movement while the

counter is being cleared when the master axis is a extension

motion control board input channel.

Movement

cancellation

47F Extension motion control board

synchronization axis error detection

An error occurred in connected axes in synchronization during

extension motion control board synchronous movement.

Check errors occurring in slave axes, master axis, and axes

moving with the same command as the master axis, or lower-

level slave axes connected in synchronization.

Movement

cancellation

497 Servo slave axis movement command speed

over error

The command from a unit commanding slave axis movement

exceeded the maximum speed. In case of extension motion

control board slave axis movement, check if the setting value

of extension motion control board output channel parameter

No. 12 exceeds the values of parameters for individual axes

No. 27 and 28, etc.

Movement

cancellation

498 Servo slave axis movement command origin

stop check timeout error

It is not possible to confirm if the slave axis operation

command is stopped.

Movement

cancellation

49A Extension motion control board command

pulse counter over error

The counter value of command pulse input channels exceeded

the range from -2,147,482,624 to 2,147,482,623 during

synchronous movement. Use the boards such that the input

pulse remains within the range above if an input channel is

used as the synchronization master axis.

Advertising