IAI America XSEL-S User Manual

Page 119

Advertising
background image

Chapter 3 Programs

111

3.3.6 Extension Motion Control Board Axis Actuator Control Command

z

XSON (extension motion control board axis servo ON)

Command, declaration

Extension

condition

(LD, A, O, AB, OB)

Input condition

(I/O/flag)

Command,

declaration

Operand 1

Operand 2

Output part

operation type

(output/flag)

E

N, Cnd

Cmnd

Operand1

Operand2

Pst

Optional

Optional

XSON

Prohibited

Prohibited

PE

[Function]

Turn the servo of extension motion control board axes specified in the XAXS command ON.

Caution : Set axis patterns using the XAXS command before executing this command. If the

command has not been executed, error No. 445 “No extension motion control board axe

pattern setting error” occurs.

[Example]

XAXS

0

1100

Set axis patterns for axes 2 and 3.

XSON

Turn the servo of specified axes ON.

z

XSOF (extension motion control board axis servo OFF)

Command, declaration

Extension

condition

(LD, A, O, AB, OB)

Input condition

(I/O/flag)

Command,

declaration

Operand 1

Operand 2

Output part

operation type

(output/flag)

E

N, Cnd

Cmnd

Operand1

Operand2

Pst

Optional

Optional

XSOF

Prohibited

Prohibited

PE

[Function]

Turn the servo of extension motion control board axes specified in the XAXS command OFF.

Caution : Set axis patterns using the XAXS command before executing this command. If the

command has not been executed, error No. 445 “No extension motion control board axe

pattern setting error” occurs.

[Example]

XAXS

0

1100

Set axis patterns for axes 2 and 3.

XSOF

Turn the servo of specified axes OFF.

Advertising
This manual is related to the following products: