Caution:

(1) Axes specified as slaves to the extension motion control board operate with operation commands by

the extension motion control board axis only. If the main CPU axis is instructed to operate, it is

treated as an invalid axis and error No. C7F “no valid axis error” occurs.

Set the resolution of the drive disabled axes with the following parameters in the same manner as

normal axes.

(2) Set extension motion control board output channel parameters No. 5 to 8, 10 to 14, and 16 according

to the main CPU control axis operating as a slave. [See 2.3.3, " Extension Motion Control Board

Parameter Setting."]

At this point, error No. 52D “Extension motion control board main CPU axis control parameter error”

occurs in the following cases.



Resolution set with an output channel parameter does not match with resolution of the main CPU

control axis.



Output channel parameter No. 12 “Maximum speed” exceeds the maximum speed of the main

CPU control axis (parameter for each axis No. 27/28).



Output channel parameter No. 13 “Maximum acceleration” exceeds the maximum acceleration of

the main CPU control axis (all-axis parameter 22).



Output channel parameter No. 14 “Maximum deceleration” exceeds the maximum acceleration of

the main CPU control axis (all-axis parameter 23).

(3) The following axes cannot be specified as a slave to the extension motion control board. Error No.

531 “Slave operation parameter error” occurs.



Rotary Movement Axis Shorter Circuit Control (Parameter for each axis No. 67 “Rotary

movement axis shorter circuit control selection” = 1)



Endless Stroke Mode (Parameter for each axis No. 68 “Linear movement axis mode selection =

1)



Synchronous Axis Setting (Parameter for each axis No. 65 “Axis No. with which the synchronous

operation is performed).

* Using the main application firmware version 1.08 or later (XSEL-P/Q), the synchronous

master axis can be specified as a slave to the extension motion control board.

(4) When the synchronous master axis is specified as a slave to the extension motion control board and

the position of the synchronous master axis is greatly different from the slave axis (in the case that

the synchronous axis is not coupled, etc.), Error No. 511 “Extension motion control axis servo

ON/OFF timeout error” might occur because the position synchronizing correction movement is

accompanied when the servo-motor is turned ON. In this case, change the extension motion control

board channel parameter No. 31 “Pulse train driver servo ON completion confirmation time” (set to

“15 seconds” at the delivery) according to the user’s system.

(5) The number of the main CPU control axes which can be specified as a slave to the extension motion

control board using the XSEL-R/S controller, is up to seven per board (All eight axes can not be

specified as slaves). When all eight axes are specified, the error No. 527: Extension motion control

board pulse output setting parameter error will occur. In order to operate all eight axes as slaves, two

extension control boards are required.