IAI America XSEL-S User Manual

Page 84

Advertising
background image

Chapter 2 Operations

76

If a value exceeding the maximum phase is set, the value is automatically corrected to the maximum

phase.

Example: If the maximum phase is 200.0

Caution: Set a value that makes the displacement width (maximum displacement - minimum

displacement) as large as possible. If the displacement width is small, the influence of

rounding error of displacement data becomes large. (The CAM shape becomes rough and

the intended output result may not be obtained.)

x

Curve types

Set the curve if you generate displacement data within a section.

For curves 0 to 21, select the “Character Displayed” check box to see the characteristics of

displacement, speed, acceleration, and jump.

Spline curve 22 calculates section definition points before and after such that an axis can pass

smoothly. If you set 99, the displacement data of the target section only is not changed when you

generate displacement data.

Input range: 0 to 22, 99

Setting value

Curve name (CAM Curve Type)

Setting value

Curve name (CAM Curve Type)

0

Straight line

12

One-dwell modified trapezoid m=1

1

Constant acceleration

13

One-dwell modified trapezoid Ferguson

2

Harmonic motion

14

One-dwell modified trapezoid m=2/3

3

Cycloid

15

One-dwell modified sine

4

Modified trapezoid

16

One-dwell trapecloid

5

Modified sine

17

No-dwell modified trapezoid

6

Modified constant speed

18

No-dwell modified constant speed

7

Asymmetric cycloid

19

NC2

8

Asymmetric modified trapezoid

20

Double harmonic motion

9

Trapecloid

21

Degree five

10

One-dwell cycloid m=1

22

Spline curve

11

One-dwell cycloid m=2/3

99

(No change)

Figure 2.4.20 Setting Value by CAM Curve Type

* Refer to “2.4.6 CAM Polarity Type” for description of graphs by CAM polarity type.

If you enter “201.0,”

“200.0” is set.

Advertising