IAI America XSEL-S User Manual

Page 180

Advertising
background image

Chapter 5 Handling Errors

172

Level

No.

Error name

Description/Action

Cold start

520 Extension motion control board undefined

DPRAM format ID error (slave CPU detection)

An error occurred at controller internal communication. The

following causes can be considered:

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and the

extension motion control board application firmware version

are not consistent (wrong combination).

Cold start

521 Extension motion control board packet

command handshake logic error

An error occurred at controller internal communication. The

following causes can be considered:

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and the

extension motion control board application firmware version

are not consistent (wrong combination).

Cold start

522 Extension motion control board DPRAM

handshake logic error (slave CPU detection)

An error occurred at controller internal communication. The

following causes can be considered:

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and the

extension motion control board application firmware version

are not consistent (wrong combination).

Cold start

523 Extension motion control board DPRAM

read/write error (slave CPU detection)

An error was detected at hardware check at starting up the

board.

The following causes can be considered.

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and the

extension motion control board application firmware version

are not consistent (wrong combination).

Cold start

524 Extension motion control board unsupported

packet command error

An error occurred at controller internal communication. The

following causes can be considered:

[1] Communication failures (controller internal communication

failures) due to noise, short-circuit, circuit failures, etc.

[2] The main CPU application firmware version and the

extension motion control board application firmware version

are not consistent (wrong combination).

Cold start

525

Extension motion control board main CPU

servo underrun detection error (slave CPU

detection)

A servo control underrun error was detected in the main CPU

board while using extension motion control boards. It is

necessary to turn the power supply on again.

Cold start

526 Extension motion control board pulse input

setting parameter error

There are errors in input channel parameter setting values of

extension motion control boards.

Check the setting values of input channel parameters No. 1

and 2.

Cold start

527 Extension motion control board pulse output

setting parameter error

There are errors in output channel parameter setting values of

extension motion control boards.

Check the setting values of output channel parameters No. 1

to 3.

Cold start

528 Extension motion control board main CPU

emergency stop signal detection error

An emergency stop signal from the main CPU was detected.

Cold start

529 Extension motion control board non-definition

main axis type error

The axis type of the main CPU control master axis is invalid.

The main CPU application firmware version and the extension

motion control board application firmware version may not be

consistent (wrong combination).

Cold start

52A Extension motion control board electronic

CAM table area assignment parameter error

The setting value of extension motion control board common

parameter No. 2 “electronic CAM table area assignment” is

invalid.

The following causes can be considered:

[1] The total number of tables exceeds 64.

[2] The total table size exceeds 64.

Cold start

52B Extension motion control board function

unsupported error

The extension motion control board does not support functions

required for the usage. Check extension motion control board

firmware version, etc. to see the functions to be used are

supported.

Advertising