123

Caution

(1) If there are any errors in synchronous electronic CAM movement settings, which are specified in

variables of operand 2, error No. 455 “Extension motion control board synchronous electronic CAM

movement setting error” occurs. Info.2 of the error list indicates the variable number of the invalid

setting (hexadecimal display).

x

Invalid variable: Master axis number (storage variable)



Specified master axis number is invalid or invalid.



Specified master axis is a synchronized-controlled slave axis or ZR unit axis (in case the

master axis is a main CPU control axis).



The specified master axis and slave axis are the same axis (in case the master axis is a

extension motion control board control axis).

x

The specified master axis is an axis or channel of a extension motion control board different

from slave axes (in case the master axis is a extension motion control board control axis or

pulse input channel)

x

Invalid variable: Stroke length/stroke end position storage position No.



The specified position No. is invalid or position data is invalid.

(2) If the master axis type of synchronous electronic CAM movement settings is specified to be main

CPU control axis, the BASE command settings become valid for the master axis number. Moreover,

the GRP command settings are invalid for position data storing stroke length and stroke end position.

(3) If multiple extension motion control boards are installed, electronic CAM table data of a board to

which slave axes are connected is used.

(4) If slave axes started synchronization while the master axis is moving, excessive speed and/or

acceleration and deceleration may occur, leading to an error. Lower the speed and/or acceleration of

the master axis when the slave axis synchronization movement is started.

(5) Excessive speed and/or acceleration/deceleration may occur during movement according to the

electric CAM table, leading to an error. In this case, change the speed, acceleration/deceleration, and

electronic CAM tables of the master axis to set speed and acceleration/deceleration permitted to the

axis.

(6) The right to use slave axes that started synchronization is owned exclusively by the slave axis

movement program that executed the XCAS command until the XSYE command (stopping

synchronous movement) is executed or the program is finished. For this reason, if the axes are used

by other programs, error No. 449 “Extension motion control board axis duplication error” occurs.

Moreover, error No. 449 occurs even if a movement command is executed on axes that finished

synchronous movement, even in the same program. Execute the XSYE command in order to perform

the next movement after synchronous movement.