Chapter 4 Parameters

148

[5] Drive disabled specification (main CPU parameter for each axis No. 166)

No.

Parameter name

Unit

Input

range

Default value

(reference)

166 Drive disabled specification

-

0~10

0

Loop back the driver output of the main CPU control axis internally so that the actual actuator

operations are not performed. By operating the drive disabled axis internally via existing operation

commands (MOVP command, etc.), it is possible to generate electronic cam main axis operations

of the extension motion control board and control the cam of slave axes to the virtual main axis.

Setting value

Item

0

Drive axis enabled (actuator connected)

1

Drive axis disabled (actuator not connected)

XSEL controller internal command

Main CPU

Extension

motion

control

board

RC

controller

Loop back driver outputs of

the main CPU internally.

X-SEL

The actuator does not

operate even if the JOG

button is clicked. Only the

current value is updated.

The actuator does not operate even if the axis is

connected (if it is set as a drive disabled axis, it is

not necessary to connect the actuator).

Command

Command