76 wiring example (logic 8) – IDEC FS1A Controller User Manual

Page 117

Advertising
background image

5-76

Wiring example (Logic 8)

An example of 3 emergency stop switches and 2 safety switches with lock switches are
connected.

K1

V+

V-

Y4
Y5
Y6
Y7

Y10
Y11
Y12
Y13
Y14
Y15

Y17

Y20

X0

X1

X2

X3

T0

T1

T2

T3

Y0

S1

Y16

24V DC

0V DC

K2

Y1

K3

Y2

K4

Y3

to PLC

S2

X5

X6

X7

T5

T6

T7

S3

S4

X10

T10

S5

X4

T4

X11

T11

X12

T12

X13

T13

X14

T14

X15

T15

K1

K2

K3

K4

X16

X17

L1

L2

K2

K1

M1

K4

K3

M2

SafetyOne

Fuse

FE

S6

S7

S8

S1,2,4 :Emergency stop switch
S3,5

:Safety switch with lock(spring lock type)

S6,7,8 :Start switch
K1...4 :Contactor
L1,2

:Solenoid of safety switch for lock release

M1,2

:Motor

Advertising