Output function, Safety output with timer, Ossd – IDEC FS1A Controller User Manual

Page 141

Advertising
background image

5-100

Output function

Safety output with timer

This function is for controlling the safety output.
As shown in Fig. 5-28, this function is comprised of a hold input (O

n

), an EDM input (I

n

), and a

safety output (Y

n

). The output of this external device monitoring input is connected to the EDM

input (I

n

).





Fig. 5-28 Safety output with timer circuit

Connects to

Equipment with force guided mechanisms, such as, contactors, safety relays.
Input of safety PLC, or another SafetyOne controller


Description of operation

The operation timing is described in Fig. 5-29 and 5-30.

When hold input is turned ON, the safety output is turned ON after confirmation that the EDM

input is ON.

When hold input is turned OFF, the safety output is turned OFF.

When the OFF-delay timer is set, after the hold input is turned OFF, the safety output is

turned OFF after the set time of the OFF-delay timer. However, the monitor outputs (Y12
and Y13) for safety output are turned OFF immediately after the hold input is turned OFF
regardless of the set time of the OFF-delay timer.

If the EDM input is not applied correctly (ON state of EDM input is detected during EDM

monitoring time (1s) after hold input is turned ON) due to an error in the safety device or input
circuit, the SafetyOne changes to the Protection state, and indicates “1” on the error LED
without turning ON the safety output. (See Fig. 5-30.)

O

n

I

n

Y

V-

Ex. Contactor, safety relay

Hold

EDM

OSSD

with

Off delay

Advertising