32 logic circuit (logic 4), 2k+1 – IDEC FS1A Controller User Manual

Page 73

Advertising
background image

5-32

Logic circuit (Logic 4)

S1

OS1

&

X0, X1

X2, X3

X4, X5

X6, X7

T12, X12, T13, X13

T10, X10, T11, X11

T14, X14

T15, X15

X16

X17

Safety input 1

Safety input 4

Safety input 3

Muting input 2

Safety input 2

Muting input 1

Start input 1

Start input 2

External device
monitor 2

External device
monitor 1

Dual Channel

Solid State

Dual Channel

Solid State

Muting input

Muting input

Dual Channel

Direct Opening

Dual Channel

Direct Opening

Single Channel

Monitor

Single Channel

Monitor

External Device

Monitor

EDM

External Device

Monitor

EDM

Control

Start

Control

Muting

function

Safety

Input

Muting

Muting

function

Safety

Input

Muting

Hold

Trigger

Self-hold

function

Hold

EDM

OSSD

with

Off de lay

Hold

EDM

OSSD

with

Off de lay

Y0

Y1

Y2

Y3

Safety output 1

Safety output 2

=2k+1

X1

X0

X3

X2

Y5

X5

X4

X7

X6

Y7

X11

X10

X13

X12

X3

X2

Y17

X7

X6

Y20

Monitor for
muting input 1

Monitor for
muting input 2

(Note2)
The muting lamp outputs are turned ON
when the muting function of the safety
inputs are effective.
Even if the muting inputs are turning
ON, the muting lamp outputs are not
turned ON, when the muting functions
are not effective because the muting
watch time is exceeded and the safety
inputs were turned OFF before turned
ON the muting inputs.

(Note2)

(Note2)

&

&

&

&

&

&

&

&

Monitor output for safety input

Monitor output for safety output

Muting lamp output

Y4

Y5

Y6

Y7

Monitor for
safety input 1

Monitor for
safety input 2

Monitor for
safety input 3

Monitor for
safety input 4

Monitor output for muting input

OS1

OS1

Y12

Y13

Y0,Y1

Y2,Y3

Monitor for
safety output 1

(Note1)
Monitor outputs for safety output 1 and
2 are turned OFF immediately
independent of set OFF-delay time.

(Note1)

&

&

Monitor for
safety output 2

(Note1)

Advertising