Start input specifications, Warning – IDEC FS1A Controller User Manual

Page 17

Advertising
background image

2-8

Start input specifications

Rated input voltage

24V DC

Input ON voltage

15.0V DC to 28.8V DC

Input OFF voltage

Open or 0V DC to 5.0V DC

Number of start input terminals

2 (X16,17)

Input current

5mA per port (at rated voltage)

Type of input

Sink type input (for PNP output), Type 1 (IEC/EN61131-2)

Cable length

Note1

100m maximum (total wiring length per 1 input)

Allowable wiring resistance

300Ω maximum

Note1. For cables longer than 30m between SafetyOne and connected devices, use grounded
shielded cables to assure electromagnetic compatibility.

Start input equivalent circuit







Start input operating range












Operating specification of start inputs are different depending on the configured logic number.
For more details, refer to “Chapter 5 LOGIC”. But the basic input specifications are not
changed.

Warning

Do not use start inputs as safety inputs. This may cause the loss of safety functions and
possible failure in the SafetyOne or peripherals.

Voltage(V)

Current

(mA)

28.8

24

15

5

0.5 3

5

6

ON area

Transition area

OFF area


In
te
rn
a

l C
ir

c

ui
t

4.7kΩ

V-

X16, X17

Advertising