5-54

●Safety input monitor outputs: Y4 to Y11

Y4 toY11 function as status monitoring of safety input devices connected to the SafetyOne.
Y4 is turned ON only in the case of teach mode is selected by mode select input.
Y5 is turned ON while both contacts of the safety device are ON. When 1 or more contacts are
OFF, the output is OFF.
Y6 to Y11 are turned ON while both contacts of the safety devices are ON. When both contacts of
the safety devices are OFF, the output is OFF.
If input monitor error is detected, pulses (1Hz) are transmitted.
Y4 outputs the status of safety input 1 (X0-T0, X1-T1).
Y5 outputs the status of safety input 2 (X2-T2, X3-T3).
Y6 outputs the status of safety input 3 (X4-T4, X5-T5).
Y7 outputs the status of safety input 4 (X6-T6, X7-T7).
Y10 outputs the status of safety input 5 (X10-T10, X11-T11).
Y11 outputs the status of safety input 6 (X12-T12, X13-T13)

●Safety output monitoring outputs: Y12 and Y13

Y12 and Y13 function as monitoring outputs that output the status of the safety outputs. When the
safety outputs are OFF, the safety output monitor output is turned OFF immediately, even if
OFF-delay timer has been set.
Y12 outputs the status of safety output 1 (Y0 and Y1). This turns ON when Y0 and Y1 are both ON.
Y13 outputs the status of safety output 2 (Y2 and Y3). This turns ON when Y2 and Y3 are both ON.

●State monitoring outputs: Y14 to Y16

Y14 to Y16 are monitoring outputs for the internal status of the SafetyOne.
Y14 turns ON when in Initial or Stop state.
Y15 turns ON in Initial, Protection or Configuration state.
Y16 turns ON when in Run state.
Refer to “Chapter 4 BASIC OPERATION”, or “Chapter 6 TROUBLESHOOTING”, for details of
each state.

Warning

Monitor outputs are not safety outputs. Do not use these to construct a safety system.

●Solenoid outputs: Y17 and Y20

Y17 and Y20 are outputs for solenoid control that are used with a safety switch with a lock.
Teach mode: In Run state, when the safety outputs are ON, the solenoid outputs are ON.
Auto mode: In Run state, when the safety outputs are OFF and 1 or more safety inputs are OFF,
the solenoid outputs are turned ON. When all safety inputs are ON, the solenoid outputs are
turned OFF, although start input is not activated.

Warning

Solenoid outputs are not safety outputs. Do not use these to construct a safety system.

Caution

Refer to "Chapter 2 PRODUCT SPECIFICATIONS" for specifications of each input and output.