2-7

Safety input specifications

Drive terminal specifications (T0, T1, T2, T3, T4, T5, T6, T7, T10, T11, T12, T13, T14, T15)

Rated drive voltage

Power supply voltage

Minimum drive voltage

Power supply voltage – 2.0V

Number of drive terminals

14

Maximum drive current

20mA per port (at 28.8V DC)

Note1

Receive terminal specifications (X0, X1, X2, X3, X4, X5, X6, X7, X10, X11, X12, X13, X14, X15)

Rated input voltage

24V DC

Input ON voltage

15.0V DC to 28.8V DC

Input OFF voltage

Open or 0V DC to 5.0V DC

Number of receive terminals

14

Rated input current

10mA per port (at rated voltage)

Type of input

Sink type input (for PNP output), Type 1(IEC/EN 61131-2)

Wiring specifications

Cable length

Note2

100m maximum (total wiring length per 1 input)

Allowable wiring resistance

300Ω maximum

Note1. The drive port generates check pulses in order to diagnose input devices and internal

circuits. (Wiring and the diagnostic function are different depending on the logic selected.
See “Chapter 5 LOGIC” for details. But the basic function is same.)

Note2. For cables longer than 30m between SafetyOne and connected devices, or wiring drive

terminals and receive terminals separately, use grounded shielded cables to assure
electromagnetic compatibility.

T

n

T

n+1

X

n+1

X

n

SafetyOne

In case of multiple safety input devices are connected

・・・

・・・

・・・

Safety input equivalent circuit Safety input operating range
















X

n

Int

e

rna

l C
ir

c

uit

2.2kΩ

V -

Voltage(V)

Current

(mA)

28.8

24

15

5

1 6

10

12

ON area

Transition area

OFF area