31 operation example (logic 4), Warning – IDEC FS1A Controller User Manual

Page 72

Advertising
background image

5-31

Operation example (Logic 4)

Contactor/
safety relay ON

Machine running

Muting lamp OFF

Safety light
curtain

PNP)

Muting sensor

PNP)

Emergency stop
switch

Safety light
curtain

PNP)

Muting sensor

PNP)

(Note) Make sure that the intersection of optical axes is within the hazardous area.

Contactor/
safety relay ON

Machine running

Muting lamp ON

Shade!

Machine stop

Shade!

Contactor/
safety relay OFF

Muting lamp OFF

Warning

When installing light curtains and muting sensors, ensure safety by referring to

IEC TS 62046 technical documents.

Emergency stop switch is released.

and

Invasions through opening are not detected.

Start input is ON

Safety outputs are ON.

Invasion through opening is detected

while muting sensors are shaded.

Safety outputs are ON.

Muting lamp outputs are ON.

Safety outputs are ON.

Invasion through opening is detected

while muting sensors are not shaded.

Safety outputs are OFF.

Safety outputs are ON.

Safety
light curtain

Muting lamp

Muting sensors

Hazardous Area

Work Objec t

(Note)

Muting lamp

Muting sensor beam blocked
Light curtain beams blocked

Hazardous Area

Light curtain blocked

Light curtain beams blocked

Light curtain beams blocked

Hazardous Area

Advertising