Logic functions – IDEC FS1A Controller User Manual

Page 121

Advertising
background image

5-80

Logic functions

This section describes the functions of each logic circuit. The logic functions are separated into
input, logic operation, and output functions in Table 5-1. Select the appropriate logic after
understanding its functionality.

Table 5-1 List of logic functions

Type

Function

Symbol

Description

Reference page

Dual channel
direct opening
input

Dual Channel

Direct Opening

This function is for connecting
safety devices with dual channel
direct opening action
mechanisms, such as
emergency stop interlock
switches.

5-82

Dual channel
dependent input

Dual Channel

D

epende nt

This function is for connecting
safety devices with a dual
channel dependent action
mechanism, such as an enabling
switch.

5-84

Dual channel
NO/NC input

Dual

Channel

NO /NC

This function is for connecting a
safety device with a dual channel
NO/NC mechanism, such as a
non-contact interlock switch.

5-86

Dual channel
solid state input

Dual Channel

Solid State

This function is for connecting
safety devices with dual channel
solid state outputs (PNP output),
such as safety light curtain or
safety laser scanner.

5-88

Mode select input

Mode

Selector

Sw itch

This function is for connecting
devices with a mode selector
function, such as mode selector
switch.

5-90

Muting input

Muting input

This function is for connecting a
sensor or other input device to
perform muting.

5-92

Monitor input

Single Channel

Monitor

This function is for connecting a
switch or sensor for use as a
start input.

5-94

Input function

External device
monitor input

External Device

Monitor

EDM

This function is for monitoring
external devices controlled by
the SafetyOne. External devices
are diagnosed for errors by
connecting a NC contact, such
as a contactor or safety relay.

5-95

Advertising