Having two motor profiles lets you store two “personalities” for motors in one inverter’s
memory. The inverter allows the final selection between the two motor types to be made
in the field through the use of an intelligent input terminal function [SET]. This
provides an extra level of flexibility needed in particular situations. See the following
table.

Parameters for the second motor have a function code of the form x2xx. They appear
immediately after the first motor’s parameter in the menu listing order. The following
table lists the parameters that have the second parameter register for programming.

Parameter Codes

Function Name

1st motor

2nd motor

Multi-speed frequency setting

A020

A220

Acceleration (1) time setting

F002

F202

Deceleration (1) time setting

F003

F203

Frequency source setting

A001

A201

Run command source setting

A002

A202

Base frequency setting

A003

A203

Maximum frequency setting

A004

A204

Multi-speed frequency setting

A020

A220

Torque boost select

A041

A241

Manual torque boost value

A042

A242

Manual torque boost frequency adjustment

A043

A243

V/f characteristic curve selection

A044

A244

V/f gain setting

A045

A245

Frequency upper limit setting

A061

A261

Frequency lower limit setting

A062

A262

Acceleration (2) time setting

A092

A292

Deceleration (2) time setting

A093

A293

Select method to use Acc2/Dec2

A094

A294

Acc 1 to Acc 2 frequency transition point

A095

A295

Dec 1 to Dec 2 frequency transition point

A096

A296

Level of electronic thermal setting

B012

B212

Electronic thermal characteristic

B013

B213

Overload restriction operation mode

B021

B221

Overload restriction level setting

B022

B222

Deceleration rate at overload restriction

B023

B223

Source of overload restriction selection

B028

B228

Terminal [1] function

C001

C201

Terminal [2] function

C002

C202

Terminal [3] function

C003

C203

Terminal [4] function

C004

C204

Terminal [5] function

C005

C205

Overload level setting

C041

C241

Motor capacity

H003

H203

Motor poles setting

H004

H204

Motor stabilization constant

H006

H206