XLT Hitachi X200 User Manual

Page 218

Advertising
background image

400V Class Inverters

 The following

tables specify the braking options for
400V class X200 inverters and the
braking torque for each option. You can
connect a single braking unit to the
inverter, or two braking units for
additional braking torque.

Use one BRD-EZ3 braking unit for the
braking torque listed in the following
table.

X200 Inverter 400V Models

Braking Torque with BRD-EZ3 Braking Unit

External resistor added

Using built-in

resistor only

HRB1 x (2)

HRB2 x (2)

HRB3 x (2)

Model Number

HP

Braking

torque

without

braking unit

A

B

A

B

A

B

A

B

004HFEF/HFU

1/2

50%

150%

150%

007HFEF/HFU

1

50%

150%

150%

015HFEF/HFU

2

50%

100%

100%

022HFEF/HFU

3

20%

60%

60%

030HFEF

4

20%

50%

50%

150%

150%

040HFEF/HFU

5

20%

40%

40%

130%

130%

150%

150%

055HFEF/HFU

7.5

20%

30%

30%

100%

100%

130%

130%

075HFEF/HFU

10

20%

20%

20%

70%

70%

100%

100%

Connect a second braking unit in parallel for additional braking torque listed in the
following table.

X200 Inverter 400V Models

Braking Torque with BRD-EZ3 Braking Unit

External resistor added

Using built-in

resistor only

HRB1 x (2)

HRB2 x (2)

HRB3 x (2)

Model Number

HP

Braking

torque

without

braking unit

A

B

A

B

A

B

A

B

004HFEF/HFU

1/2

50%

150%

150%

007HFEF/HFU

1

50%

150%

150%

015HFEF/HFU

2

50%

150%

150%

022HFEF/HFU

3

20%

130%

130%

030HFEF

4

20%

100%

100%

040HFEF/HFU

5

20%

70%

70%

055HFEF/HFU

7.5

20%

50%

50%

150%

150%

075HFEF/HFU

10

20%

40%

40%

140%

140%

Inverter

+



Braking

unit

Braking

unit

5

7

5

−7

Inverter System

Accessories

Advertising