3 replacing the installation gasket, 3 replacing the installation gasket -4, Replacing the installation gasket – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 103: 4 5.3 replacing the installation gasket

Advertising
background image

ST3000 Series Hardware Manual

5-4

5.3

Replacing the Installation Gasket

The installation gasket provides protection against dust and moisture.

„ Installation Gasket Attachment Procedure

(1)

Place the ST on a flat, level surface facing the display face downwards.

(2)

Remove the gasket from the ST.

(3)

Attach the new gasket to the ST. Be sure to insert the gasket into the ST’s groove so that the gasket’s

groove sides are vertical.

(4)

Check that the gasket is attached correctly to the ST.

• A gasket which has been used for a long period of time may have scratches or

dirt on it, and could have lost much of its water resistance. Be sure to change the

gasket at least once a year, or when scratches or dirt become visible.

• The ST unit installation gasket’s model number is as follows.

ST-3200 Series

ST400-WP01

ST-3300 Series

CA3-WPG6-01

ST-3400 Series

CA5-WPG8-01

ST-3500 Series

CA5-WPG10-01

ST Rear Face

Gasket Seam

Gasket

Installation
Groove

Advertising