When using the ac type – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 87

Advertising
background image

ST3000 Series Hardware Manual

4-8

„ When using the AC Type

‹ Power Cord Specifications

‹ Connecting the Power Cord

When connecting the AC type power cord, be sure to follow the procedures given below.

(1)

Be sure that the ST’s power cord is not plugged in to the power supply.

(2)

Remove the Terminal Strip’s clear plastic cover.

(3)

Remove the screws from the two (2) terminals (L, N) and FG (Frame Ground) terminal, position the

Ring Terminals and reattach the screws. (Check each wire to make sure the connections are correct.)

(4)

Reattach the Terminal Strip’s clear plastic cover.

AC Power Cord

Grounding Wire

Power Cord

Double-insulated Wire

1.25 to 2.0mm

2

(16-14 AWG)

1.25 to 2.0mm

2

(16-14 AWG)

Recommended
Ring Terminal

*1

*1.

In order to prevent a short circuit caused by loose screws, make sure to use a

crimp-type terminal with insulating sleeve.

V2-MS3 compatible

(J.S.T. Mfg. Co., Ltd.)

V2-P4 compatible
(J.S.T. Mfg. Co., Ltd.)

• The torque required to tighten these screws are as follows:

Terminal Block: 0.5 to 0.6N

•m [5-7Lb•In.]

FG (Frame Ground) Terminal: 0.6 to 0.7N

•m

less than
6.0mm
[0.24in.]

∅3.2mm [0.13in.]
or more

less than
7.0mm
[0.28in.]

∅4.3mm [0.17in.]
or more

FG (Frame Ground) Terminal