2 wiring precautions, 1 connecting the power cord, 2 wiring precautions -7 – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 86: 1 connecting the power cord -7, Wiring precautions, 7 4.2 wiring precautions

Advertising
background image

Chapter 4 Installation and Wiring

4-7

4.2

Wiring Precautions

This section describes the procedures and precautions for wiring power cords.

4.2.1

Connecting the Power Cord

To avoid an electric shock, prior to connecting the ST unit’s power cord terminals to the

power terminal block, confirm that the ST unit’s power supply is completely turned OFF, via

a breaker, or similar unit.

Supplying a power voltage other than that specified will damage the power source and the

ST unit.

Since there is no power switch on the ST unit, be sure to attach a breaker-type switch to its

power cord.

When the FG terminal is connected, be sure the wire is grounded.

• When the FG terminal is connected, be sure the wire is grounded. Not grounding

the ST unit will result in excess noise and vibration.

• ST Series (except AST-3211A, AST-3302B COM2) have the SG (signal ground)

connection and the FG (frame ground) connection inside.

When connecting the SG wire to another device, be sure that the design of the

system/connection does not produce a ground loop.

Advertising