Yokogawa DAQWORX User Manual

Page 99

Advertising
background image

3-21

IM WX101-01E

1

2

3

4

5

6

7

8

9

Index

Using Data Monitor

3. In the “Log” tab panel (alarm log display) of the alarm monitor, drag the mouse from

one line to another.

The cursor’s values at the start and end points of the selected area are displayed in

the “Cursor’s Value” dialog box.

Values at the start and end points of the selected area are displayed.

Clearing the Cursors

To clear the cursors, perform the operation shown below.

However, cursors will disappear without doing the following operation when the monitor’s

display updating is resumed.

Procedure

1. From the menu bar, select “View” then “Hide Cursor.”

When the cursors are cleared, no data is displayed in the “Cursor’s Value” dialog

box’s table.

Note

The “Cursor’s Value” dialog box disappears when the monitor’s display updating is resumed.

3.4 Using the Cursors