Commissioning – Sterling RT User Manual

Page 21

Advertising
background image

20

SV01H

Commissioning

Display

INDICATING LEDs (on 4-character display)

FWD

FWD LED: Indicate the present rotation direction is forward. Refer to ROTATION description above.

REV

REV LED: Indicate the present rotation direction is reverse. Refer to ROTATION description above.

AUTO

AUTO LED: Indicates that the drive has been put into Auto mode from one of the TB13 inputs (P121…P124 set
to 1…7). Also indicates that PID mode is active (if enabled).

RUN

RUN LED: Indicates that the drive is running.

L M

s t

LED: Indicates that the s t are the active reference.

NOTE
If the keypad is selected as the auto reference (P121…P124 is 6) and the corresponding
TB-13 input is closed, the AUTO LED and s t LEDs will both be on.

FUNCTIONS THAT FOLLOW ARE APPLICABLE TO SMV DRIVES 15HP (11kW) AND GREATER

CTRL

CTRL
The CTRL pushbutton selects the start and speed reference control sources for the drive.

Press [

] mode button to accept the new control mode selection.

CTRL LEDs

START CONTROL

REFERENCE CONTROL

REMOTE

LOCAL

MAN
AUTO

[LOCAL] [MAN]

Keypad

P101 Settings

REMOTE

LOCAL

MAN
AUTO

[LOCAL] [AUTO]

Keypad

Terminal 13x Settings

REMOTE

LOCAL

MAN
AUTO

[REMOTE] [MAN]

Terminal Strip

P101 Settings

REMOTE

LOCAL

MAN
AUTO

[REMOTE] [AUTO]

Terminal Strip

Terminal 13x Settings

If P100 = 6 the CTRL button is used to toggle
start control between the terminal strip [REMOTE]
and the keypad [LOCAL]

- REM/LOC LED indicating the present start control source is ON
- Press [CTRL]; the LED for other start control source will blink
- Press [M] within 4 sec to confirm the change
- Blinking LED will turn ON (the other LED will turn OFF)

If P113 = 1 the CTRL button is used to toggle
reference control between the TB-13x setup
[AUTO] and P101 [MANUAL]

- AUT/MAN LED indicating present reference control is ON
- Press [CTRL]; the other reference control will blink
- Press [M] within 4 sec to confirm change
- Blinking LED will turn ON (the other LED will turn OFF)

If P100 = 6 and P113 = 1, it is possible to
change the start and reference control sources at
the same time

Advertising
This manual is related to the following products:

PV, MS, ME, AH