Commissioning – Sterling RT User Manual

Page 26

Advertising
background image

25

SV01H

Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

P 0

Start Method

0

0 Normal
1 Start on Power-up

Drive will automatically start when power is
applied.

2 Start with DC Brake

When start command is applied, drive will
apply DC braking according to P174, P175
prior to starting the motor

3 Auto Restart

Drive will automatically restart after faults, or
when power is applied.

4 Auto Restart with DC Brake

Combines settings 2 and 3

5 Flying Start/Restart #1

• Drive will automatically restart after faults,

or when power is applied.

• After 3 failed attempts, drive will Auto

Restart with DC brake.

• P110 = 5: Performs speed search, starting

at Max Frequency (P103)

• P110 = 6: Performs speed search, starting

at the last output frequency prior to faulting
or power loss

• If P111 = 0, a flying START is performed

when a start command is applied.

6 Flying Start/Restart #2

NOTE
• P110 = 0, 2: Start command must be applied at least 2 seconds after power-up;

fault will occur if start command is applied too soon.

• P110 = 1, 3…6: For automatic start/restart, the start source must be the terminal

strip and the start command must be present.

• P110 = 2, 4…6: If P175=999.9, dc braking will be applied for 15s.
• P110 = 3…6: Drive will attempt 5 restarts; if all restart attempts fail, drive displays

(fault lockout) and requires manual reset.

• P110 = 5, 6: If drive cannot catch the spinning motor, drive will trip into . fault.

WARNING!
Automatic starting/restarting may cause damage to equipment and/or injury to personnel! Automatic starting/restarting
should only be used on equipment that is inaccessible to personnel.

P 1

Stop Method

0

0 Coast

Drive’s output will shut off immediately upon
a stop command, allowing the motor to coast
to a stop

1 Coast with DC Brake

The drive’s output will shut off and then the DC
Brake will activate (refer to P174, P175)

2 Ramp

The drive will ramp the motor to a stop
according to P105 or P126.

3 Ramp with DC Brake

The drive will ramp the motor to 0 Hz and then
the DC Brake will activate (refer to P174, P175)

Rotation

0

0 Forward Only

If PID mode is enabled, reverse direction is
disabled (except for Jog).

1 Forward and Reverse

Advertising