Troubleshooting and diagnostics, 2 drive configuration messages – Sterling RT User Manual

Page 43

Advertising
background image

42

SV01H

Troubleshooting and Diagnostics

Status / Warning

Cause

Remedy

L

Sleep Mode is active

Refer to P240...P242

P

Start Pending

The drive has tripped into a fault and
will automatically restart (P110 = 3...6)

To disable Auto-Restart, set P110
= 0...2

PID Mode disabled.

Drive has been taken out of PID Mode.
Refer to P200.

o

Output frequency = 0 Hz
(outputs U, V, W inhibited)

Stop has been commanded from the
keypad, terminal strip, or network

Apply Start command (Start Control
source depends on P100)

5.2

Drive Configuration Messages

When the Mode button is pressed and held, the drive’s display will provide a 4-digit code that indicates how the
drive is configured. If the drive is in a Stop state when this is done, the display will also indicate which control source
commanded the drive to Stop (the two displays will alternate every second).

Configuration Display

Format = x.y.zz

x = Control Source:

= Local Keypad
= Terminal Strip
= Remote Keypad
= Network

y = Mode:

= Speed mode
= PID mode
= Vector Torque mode

zz = Reference:

= Keypad s t

U

= 0-10 VDC (TB-5)

1

= 4-20 mA (TB-25)
= Jog
= Network
= MOP

1

= Preset 1...7

Example:

L

= Local Keypad Start control, Speed mode, Keypad speed reference

.

= Terminal Strip Start control, PID mode, 0-10 VDC setpoint reference

= Network Start control, Vector Torque mode, Preset Torque #2 reference

Stop Source Display

Format = x

S

s

= Stop command came from Local Keypad
= Stop command came from Terminal Strip

t

= Stop command came from Remote Keypad
= Stop command came from Network