SV01H

Commissioning

Code

Possible Settings

IMPORTANT

No.

Name

Default Selection

P 4

Digital Output
Inversion

P144

Invert

P142

Invert

P140

0

NO

NO

1

NO

YES

2

YES

NO

3

YES

YES

Used to invert the selections for P140 (Relay
Output) and P142 (TB-14 Output).
EXAMPLE: When P140 = 6 (AT SPEED), the
relay is energized when output frequency =
commanded frequency. IF P144=1 or 3, then
P140 is inverted (INVERSE AT SPEED) and the
relay is energized when the output frequency
does

not equal the command frequency.

NOTE
Inverting P140 or P142 when the parameter is set to NONE (0) will result in the output
being energized continuously.
NOTE

For SMVector drives rated at 0.33 to 10 HP (0.25 to 7.5 kW), P144 is only available
with software versions 3.0 and higher (refer to P501).

Loss of Load
Threshold

0

0

{%}

200

P140, P142 = 10: Output will energize if motor
load falls below the P145 value longer than
the P146 time

p

Loss of Load Delay

0.0

0.0

{s}

240.0

p 0

TB-30 Output

0

0 None

2-10 VDC signal can be converted to 4-20 mA
with a total circuit impedance of 500

1 0-10 VDC Output Frequency
2 2-10 VDC Output Frequency
3 0-10 VDC Load
4 2-10 VDC Load
5 0-10 VDC Torque
6 2-10 VDC Torque
7 0-10 VDC Power (kW)
8 2-10 VDC Power (kW)
9 Network Controlled

Requires optional communication module
(refer to the network module documentation).

p 2

TB-30 Scaling:
Frequency

60.0

3.0

{Hz}

2000

If P150 = 1 or 2, sets the frequency at which
output equals 10 VDC

TB-30 Scaling: Load

200

10

{%}

500

If P150 = 3 or 4, sets the Load (as a percent
of drive current rating) at which output equals
10 VDC.

p 4

TB-30 Scaling:
Torque

100

10

{%}

1000

If P150 = 5 or 6, sets the Torque (as a percent
of motor rated torque) at which output equals
10 VDC

TB-30 Scaling:
Power (kW)

1.0

0.1

{kW}

200.0

If P150 = 7 or 8, sets the power at which
output equals 10 VDC

Advertising