Appendix appendix a, A.1 permissable cable lengths – Sterling RT User Manual

Page 47

Advertising
background image

46

SV01H

Appendix

Appendix A

A.1

Permissable Cable Lengths

The table herein lists the permissable cable lengths for use with an SMV inverter with an internal EMC filter.

NOTE
This table is intended as a reference guideline only; application results may vary. The values in this
table are based on testing with commonly available low-capacitance shielded cable and commonly
available AC induction motors. Testing is conducted at worst case speeds and loads.

Maximum Permissible Cable Lengths (Meters) for SMV Model with Internal EMC Filters

Mains

Model

4 kHz Carrier

(P166 = 0)

6 kHz Carrier

(P166 = 1)

8 kHz Carrier

(P166 = 2)

10 kHz Carrier

(P166 = 3)

Class A

Class B

Class A

Class B

Class A

Class B

Class A

Class B

240 V, 1-phase

(2/PE)

ESV251GG2SFG

38

12

35

10

33

5

30

N/A

ESV371GG2SFG

38

12

35

10

33

5

30

N/A

ESV751GG2SFG

38

12

35

10

33

5

30

N/A

ESV112GG2SFG

38

12

35

10

33

5

30

N/A

ESV152GG2SFG

38

12

35

10

33

5

30

N/A

ESV222GG2SFG

38

12

35

10

33

5

30

N/A

400/480 V,3-phase

(3/PE)

ESV371GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV751GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV112GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV152GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV222GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV302GG4TFG

30

4

25

2

20

N/A

10

N/A

ESV402GG4TFG

54

5

48

3

42

2

N/A

N/A

ESV552GG4TFG

54

5

48

3

42

2

N/A

N/A

ESV752GG4TFG

54

5

48

3

42

2

N/A

N/A

NOTE: The “