DDS Interface Configuration Command Set

61200510L1-35E

Copyright © 2005 ADTRAN

580

clock source [line | internal]

Use the clock source command to configure the source timing used for the interface. The clock specified
using the clock source command is also the system master clock. Use the no form of this command to
return to the default value.

Syntax Description

internal

Configures the unit to provide clocking using the internal oscillator.

line

Configures the unit to recover clocking from the DDS circuit.

Default Values

By default, the clock source is set to line.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, and 4000 Series units.

Command History

Release 1.1

Command was introduced.

Functional Notes

When operating on a DDS network, the clock source should be line. On a point-to-point private network,
one unit must be line and the other internal.

Usage Examples

The following example configures the unit to recover clocking from the circuit:

(config)#interface dds 1/1

(config-dds 1/1)#clock source line