Agilent Technologies 16700 User Manual

Page 107

Advertising
background image

107

Pattern Generation Modules Specifications
and Characteristics

Agilent 10473A 3-State 2.5 Volt Data Pod

Output type

74AVC16244

3-state enable

negative true, 38 K

Ω to GND, enabled on no connect

Maximum clock

300 MHz

Skew [1]

typical < 1.5 ns; worst case = 2 ns

Recommended lead set

Agilent 10498A

74AVC16244

[1] Typical skew measurements made at pod connector with approximately 10 pF/50 K

Ω load to GND; worst case

skew numbers are a calculation of worst case conditions through circuits. Both numbers apply to any channel
within a single or multiple module system.

[2] Channel 7 on the 3-state pods has been brought out in parallel as a non 3-state signal. By looping this output back

into the 3-state enable line, the channel can be used as a 3-state enable.

Agilent 10469A 5 volt PECL Data Pod

Output type

100EL90 (5V) with 348 ohm pulldown to ground and 42 ohm in series

Maximum clock

300 MHz

Skew [1]

typical < 500 ps; worst case = 1 ns

Recommended lead set

Agilent 10498A

Agilent 10471A 3.3 volt LVPECL Data Pod

Output type

100LVEL90 (3.3V) with 215 ohm pulldown to ground and
42 ohm in series

Maximum clock

300 MHz

Skew [1]

typical < 500 ps; worst case = 1 ns

Recommended lead set

Agilent 10498A

42

348

100EL90

42

215

100LVEL90