Normal Mode

Since higher priority events take precedence over lower priority events, the UDACT-F will transmit higher priority
events before sending the lower priority events. Priorities are as follows:

Event Activations

1.

General Alarm

2.

Zone/Point Alarm #N

3.

General Supervisory

4.

Zone/Point Supervisory #N

5.

General System Trouble

6.

AC Power Loss

7.

Zone/Point Trouble #N

8.

Low Battery

9.

Telco Primary Line Fault

10.

Telco Secondary Line Fault

11.

NAC Fault Code

12.

Communication Trouble, Primary Number

13.

Communication Trouble, Secondary Number

14.

EIA-485 Communication Bus Trouble

15.

System Off Normal Code

16.

System Automatic Test Report

17.

System Abnormal Automatic Test Report

18.

Manual Activated Test Report

Event Restorals

19.

General Alarm Restoral

20.

Zone/Point Alarm #N Restoral

21.

General Supervisory Restoral

22.

Zone/Point Supervisory #N Restoral

23.

General System Trouble Restoral

24.

AC Power Loss Restoral

25.

Zone/Point Trouble #N Restoral

26.

Low Battery Restoral

27.

Telco Primary Line Fault Restoral

28.

Telco Secondary Line Fault Restoral

29.

NAC Fault Code Restoral

30.

Communication Trouble, Primary Number Restoral

31.

Communication Trouble, Secondary Number Restoral

32.

EIA-485 Communication Bus Trouble Restoral

33.

System Off Normal Code Restoral

Note: #N represents the number of zones or devices in alarm or trouble. This is valid for all formats except
Ademco Contact ID.

For all formats, the 'general' reports are always transmitted (unless disabled). The zone or point information may fol-
low the general report if enabled.

For all pulsed formats and both Ademco Express formats, the zone/point report is repeated per the total number of
zones or points activated once factory default entries of zero are removed. See Table 3-2 on page 34, Table 3-3 on
page 35, Table 3-4 on page 36, Table 3-5 on page 37, Table 3-6 on page 38 and Table 3-7 on page 39. When Ademco
Contact ID format is used, the actual zone or point activated is identified in the report.