P. 49 Additional sentences at

“6.4.2 How to measure PI”

DAR Simultaneous display

DAR value is displayed during PI measurements and the measured results are being displayed.

TIME 1 and 2 values for DAR are the ones pre-set in the DAR mode. Refer to 6.5.2 How to measure DAR

and set the time for DAR.

In case that DAR TIME 2 value is higher than PI TIME 2 value, DAR value isn

’t displayed on the LCD. A

measurement stop when the PI TIME 2 comes. PI value isn

’t displayed in the DAR measurement mode.

P. 52 Amendments to the illustration and table at

“6.4.3 Measured Result”

Displayed Items

Details

Insulation Resistance

Measured insulation resistance value

PI Resistance at TIME1,2

PI Resistance value at TIME1 and TIME2

DAR Resistance at TIME1,2

DAR Resistance value at TIME1 and TIME2

PI

Polarization Index value

Pre-set Voltage

Pre-set output voltage value

Output Voltage

Voltage being output

Current value

Current value being measured

Capacitance

Capacitance measured at discharge

DAR

Dielectric Absorption Ratio

P. 61 Additional sentence at

“6.7.2 Measured Setting Items”

In the SV measurement mode, measurements continue after the preset Step time (V5) comes and

automatically stop when 90 min pass.

P.70 Amendments to the description at

“6.11.3 Auto-power-off Function”.

The instrument automatically turns off when approx 10 min pass after a measurement with Timer function

activated or 90 min of continuous measurement in SV mode completes.

PI value

DAR Resistance

at TIME1,2

PI Resistance

at TIME1,2

電圧設定値

Pre-set Voltage

出力電圧値

Output Voltage

Capacitance

DAR value

PI値

Current value

絶縁抵抗値

Insulation