Individual parameters, Input parameters, Process variable - word parameter 1 – West Control Solutions N6600 User Manual

Page 45

Advertising
background image

4.4

INDIVIDUAL PARAMETERS

4.4.1 Input Parameters

4.4.1.1 PROCESS VARIABLE - Word Parameter 1

This Read Only word parameter indicates the current value of the process

variable.

O075-4

4-9

PM-0075

Parameter

No.

Notes

Low Heater Break Alarm value

31

0 - 100% and OFF or 0.1A/1A -

Heater Current High Scale Limit (see

Subsection 4.4.6.5)

High Heater Break Alarm value

32

0 - 100% and OFF or 0.1A/1A -

Heater Current High Scale Limit (see

Subsection 4.4.6.6)

Heater Current

33

Read Only

AM Key Usage

34

Read Only

Alarm 1 Hysteresis

35

1 - 250 or 0.1 - 25.0 (as per Heater

Current High Scale Limit)

Alarm 2 Hysteresis

36

1 - 250 or 0.1 - 25.0 (as per Heater

Current High Scale Limit)

Soft Start Setpoint

37

Soft Start Time

38

Soft Start Time Remaining

39

Read Only - Returns 0 if not in Soft

Start

Manufacturer ID

121

Read Only - 231 (representing “W1”)

Equipment ID

122

Read Only - number 6600

NOTES

1. The values of Word Parameters 29 and 30 are always to 0.1A resolution.

2. If Heater Break Alarms are set to Absolute Current Mode, values of Word

Parameters 31 and 32 will be to 0.1A resolution.

3. If Heater Current High Scale Limit (Word Parameter 29) is set to >20A, the

Controller operates to 1A resolution, in which case all the above Word Parameters’

least significant decimal digit will return ) and, in Write operations, that digit will be

truncated.

Table 4-3 MODBUS Word Parameters (Cont.)