Profiler Option

59407, Issue 1 – March 2008

10 The Profiler Option

The features covered in this section are only available on models fitted with the Profiler
(Setpoint Programmer) option. If the instrument also has the Data Recorder option fitted, it’s
Real Time Clock is used to expand the profiling capabilities by adding Day & Time profile
start options, releasing of hold segments at a specific time of day and changing the power fail
recovery option based on the length of time the power has been off for. These features are
explained below and in the Profiler Setup and Profile Control menus (refer to section 7)

Introduction

The Profiler option allows the user to store up to 255 profile segments, shared between a
maximum of 64 Profiles. Each profile controls the value of the setpoint over time; increasing,
decreasing or holding its value as required. If fitted, Profiler options are added to the Main
Menu as well as the Operation Mode.

Profiler Enabling

Controllers supplied without the Profiler option installed can be upgraded in the field by
purchasing a licence code number from your supplier. Refer to the Field Upgrade information
(Section 3) for more details.

Profile Components

The General Profile Configuration settings decide how profiles can be Run, Held or Aborted.
These settings apply to all profiles. Each profile has it’s own header information plus 1 or
more segments.

Profile Header & Segment Information

The profile header contains information about how the profile starts and stops, the power
loss recovery action and if it should repeat.

Note:

Profile Header information is stored to memory as the Segment creation sequence begins.
No profile is created if you exit before this point.

Segments can be ramps, dwells, steps or special segments such as holds, ends or joins.
Note: Segment information is stored as each segment is created, but the profile remains
invalid until an end or join segment is defined.