125

Custom Arb Waveform Generator

Working with Filters

Working with Filters

This section provides information on using predefined (

page 126

) and user-defined (

page 127

) FIR filters.

NOTE

The procedures in this section apply only to filters created in either the Custom Arb
Waveform Generator or Custom Real Time I/Q Baseband mode; they do not work with
downloaded files, such as those created in Matlab.

The

Filter

menu selections enable you to apply a filter to the generated signal, define a finite impulse

response (FIR) filter, change a Root Nyquist or Nyquist filter alpha, change a Gaussian filter BbT, or restore
all filter parameters to their default state. In Custom Real Time I/Q mode, you can also optimize a FIR filter
for Error Vector Magnitude (EVM) or Adjacent Channel Power (ACP)

Predefined Filters (

Filter

>

Select

)

Root Nyquist

is a root-raised cosine pre-modulation FIR filter. Use a Root Nyquist filter when you want to

place half of the filtering in the transmitter and the other half in the receiver. The ideal root-raised cosine
filter frequency response has unity gain at low frequencies, the square root of raised cosine function in
the middle, and total attenuation at high frequencies. The width of the middle frequencies is defined by
the roll off factor or Filter Alpha (0 < Filter Alpha < 1).

Nyquist

is a raised cosine pre-modulation FIR filter. You can use a Nyquist filter to reduce the bandwidth

required by a signal without losing information. The ideal raised cosine filter frequency response
comprises unity gain at low frequencies, a raised cosine function in the middle, and total attenuation at
high frequencies. The width of the middle frequencies is defined by the roll off factor or Filter Alpha (0
< Filter Alpha < 1).

Gaussian

is a Gaussian pre-modulation FIR filter.

User FIR

enables you to select from a Catalog of FIR filters; use this selection if the other predefined FIR

filters do not meet your needs. For more information, see

Define User FIR

, below.

Rectangle

is a rectangular pre-modulation FIR filter.

APCO 25 C4FM

is an APCO 25-specified C4FM filter; this is a Nyquist filter with an alpha of 0.200 that is

combined with a shaping filter.

Filter Parameters

Define User FIR

is available for when the predefined FIR filters do not meet your needs. You can define

FIR coefficients and set the oversample ratio (number of filter coefficients per symbol) to be applied to a
custom FIR filter.