Input menu, Jmpø1 jmpø2 input menu (continued), Input jumper settings – Athena Technologies 16C User Manual

Page 20: Temperature input type, Linear input type

Advertising
background image

17

Input Type JMPØ1 JMPØ2

Thermocouple Out Out

RTD Out Out

Voltage <100 mV Out Out

Voltage >100 mV In Out

Current Process In In

16

Input Menu

JMPØ1

JMPØ2

Input Menu (continued)

Display Parameter Selection

Input Type 100 ohm

compressed RTD

0-20 mA

4-20 mA

0-10 mV

0-50 mV

0-100 mV

10-50 mV

0-1 V

0-5 V

0-10 V

1-5 V

Input Jumper Settings

Note: When you ordered your controller, an input type was specified and the controller was set up
accordingly and calibrated for that input type at the factory. If you decide to change input type from
thermocouple to RTD or vice-versa, you will need to recalibrate the controller unless you ordered the
“Calibrate All” option. (Refer to page 56 for information on recalibration.) If you are changing from a
temperature input type to a linear input type, you MUST recalibrate and change the jumper settings as
indicated in the above table.

Temperature Input Type

Display Parameter Selection

Bias (Display offset) -100 to 100
Lower Setpoint Limit Span of Sensor
Upper Setpoint Limit Span of Sensor
Filtering 0.1-10.0 sec.

Linear Input Type

Display Parameter Selection

Bias (Display offset) -100 to 100
Low Scale -1999 to 9999
High Scale -1999 to 9999
Lower Setpoint Limit Span of Sensor
Upper Setpoint Limit Span of Sensor
Filtering 0.1-10.0 sec.

Input Menu