Figure 2. Case Dimensions

Prior to mounting the Series C in your panel, make sure that

the cutout opening is of the right size, 1.771” x 1.771” (45

mm x 45 mm), and deburred to enable a smooth fit. A mini-

mum of 4” (100 mm) of depth behind the panel is required.

Figure 3. Series C Mechanical Components
Insert the Series C through the front panel cutout and slide

the mounting collar back onto the unit from behind the

panel. Push the mounting collar up tight to the back of the

mounting panel.

2.100"

(53.3mm)

O1

O2

A1

A2

F1

F2

PV

SV

2.100"

(53.3mm)

4.654"

(118.21mm) 3.937"

(100 mm)

0.717"

(8.21 mm)

1.750"

(44.5 mm)

Bezel

Case Clip

Grips

Gasket

Customer Panel

When properly

installed through

a NEMA enclosure,

the integrity of the

enclosure will be

maintained and will

remain “Watertight.”