Multiple frequency power sweep 5-14, Power sweep, two tone operations, measurement – Anritsu ME7840A User Manual

Page 75

Advertising
background image

Multiple Frequency
Power Sweep

Procedure.

n

Measurement Type: Drop down options. Set to

“Multi Freq Power Sweep ” for this test.

n

Main Tone (MHz): CW Frequency setting for

source 1. The user may set a lower tone and upper
tone. The software will sweep three frequencies
(the two input plus one between) and the RF input
power to produce the display data.

n

Offset (kHz): Offset frequency for Source 2

(Source 2 will be set to Main Tone + Offset).

n

Start Power (dBm): Power will be swept starting

at the start power (input RF power to AUT). Both
sources are simultaneously set to each power set-
ting. The stop power is also entered in the “to” win-
dow.

n

Data Points: Number of data points in power

sweep.

n

Increment Power (dBm): Value to increment

power for each data point (calculated and dis-
played only).

n

Source Attn (dB):Value of Source attenuation, be-

tween 0 and

-70 (calculated and displayed only).

n

Drain Current Checkbox: When checked the

drain current is measured and power added effi-
ciency is calculated and displayed.

n

PStop Level (dB):Provides the ability to set the

PStop value based on the level of gain compres-
sion. Drop down options include compression levels
of 1 dB through 10 dB in 1 dB increments, and
OFF. If OFF is selected, then the P Stop equals the
value entered in the “to” window above. If the se-
lected compression occurs, PStop for all subse-
quent power sweeps is reset to one increment be-
fore the P

in

value where this compression level is

reached.

POWER SWEEP, TWO TONE

OPERATIONS, MEASUREMENT

5-14

ME 7840A OMM

Advertising