Enww control-panel messages 113 – HP LaserJet 5200 Printer series User Manual

Page 125

Advertising
background image

Control panel message

Description

Recommended action

a message that indicates which tray the job is
being printed from.

Processing... from tray<X>

The printer is actively processing a job from
the designated tray.

No action necessary.

Receiving upgrade

A firmware upgrade is in progress.

Do not turn the printer off until the printer
returns to Ready.

Request accepted please wait

The printer has accepted a request to print an
internal page, but the current job must finish
printing before the internal page will print.

No action necessary.

Resend upgrade

The firmware upgrade was not successful.

Attempt the upgrade again.

Restoring factory settings

The printer is restoring factory settings.

No action necessary.

Restoring...

The printer is restoring settings.

No action necessary.

RFU LOAD ERROR

An error has occurred during a firmware
upgrade.

1.

Reinstall the firmware.

2.

If the problem persists, contact
HP Support.

Rotating motor

alternates with

To exit press STOP key

The printer is testing a motor.

Press

Stop

to stop this test.

SANITIZING DISK X% COMPLETE

alternates with

DO NOT POWER OFF

The memory disk is being sanitized. This
process might take up to an hour. During this
time, no jobs can be printed.

Do not turn off the printer. Wait for the
process to complete.

The printer automatically restarts at the end
of the sanitation process.

Setting saved

A menu selection has been saved.

No action necessary.

SIZE MISMATCH IN TRAY XX

alternates with

Ready

The tray is loaded with a media size that is
different than the size for which the tray is
configured. Printing can continue from other
trays, but not from this one.

1.

Make sure the media guides are
adjusted correctly.

2.

In the PAPER HANDLING menu,
configure the tray for the correct size.

Sleep mode on

The printer is in the sleep mode. Any button
press or the receipt of data clears sleep
mode.

No action necessary. The printer
automatically exits sleep mode.

STANDARD TOP BIN FULL

alternates with

Remove all paper from bin

The output bin is full. Printing cannot
continue.

Empty the output bin. Printing resumes
automatically.

Tray X <TYPE> <SIZE>

alternates with

To change size or type press

The printer is reporting the current
configuration of tray X.

No action necessary.

Press

to clear the message.

Press

to change the type or size.

See

Configuring trays on page 53

for more

information.

TRAY XX EMPTY <TYPE> <SIZE>

alternates with

The tray is empty, but the current print job
does not require this tray.

Fill the tray. The message indicates the type
and size of media for which the tray is
currently configured.

ENWW