5.

Click Set. A confirmation message appears.

6.

Click OK. Settings are applied to the Port table, but not to the array. Changes are indicated in blue.

7.

Click Apply. A confirmation message appears.

8.

Click OK. Settings are applied to the array.

Specifying a Fibre Channel port's data transfer speed

You can adjust the data transfer speed for Fibre Channel ports to optimize system performance. For more

information, see

Data transfer speed for Fibre Channel ports

.

1.

Start LUN Manager, and display the Port pane (

Figure 21

).

2.

In the Package tree, select the Fibre folder or a Fibre Channel channel adapter.
• If you select the Fibre folder, the Port table displays a list of Fibre Channel ports in the array.
• If you select a channel adapter, the Port table displays a list of Fibre Channel ports on

the channel adapter.

3.

In the Port table or Select a Port list, select a port. The Change Port Mode box displays information

about the selected ports.

4.

In the Host Speed list, select the data transfer speed.

5.

Click Set. A confirmation message appears.

6.

Click OK. Settings are applied to the Port table, but not to the array. Changes are indicated in blue.

7.

Click Apply. A confirmation message appears.

8.

Click OK. Settings are applied to the array.

Switching between Standard, High Speed, and Initiator/External MIX mode

Channel adapter boards (PCB: printed circuit board) take Standard, High Speed, or Initiator/External

MIX mode. You can apply High Speed mode to channel adapters to improve system performance. Or

you can apply Initiator/External MIX mode so that one port can be used both as an initiator port for

Continuous Access XP or Continuous Access XP Journal and as an external port applied to a remote

command device. Be aware that you can only apply High Speed or Initiator/External MIX mode to

channel adapters that satisfy certain requirements. For more information, see

Standard, High Speed,

and Initiator/External MIX modes

. For instructions on defining remote command devices, see the

HP StorageWorks External Storage XP user guide.

1.

Start LUN Manager, and display the Port pane (

Figure 21

).

2.

In the Package tree, double-click the Fibre folder. The tree displays a list of CHA (Fibre Channel

channel adapter) packages.

3.

Double-click a channel adapter icon (

,

, or

) to display port blocks.

• The

icon indicates a block of ports in Standard mode.

• The

icon indicates a block of ports in High Speed mode.

• The

icon indicates a block of ports in Initiator/External MIX mode.

4.

Do one of the following:
• To change the mode of a block of ports from Standard to High Speed or Initiator/External

MIX, right-click the

icon, and select High Speed Mode/MIX Mode.

• To change the mode of a block of ports from High Speed to Standard, right-click the

icon, and select Standard Mode.

• To change the mode of a block of ports from Initiator/External MIX mode to Standard,

right-click the

icon, and select Standard Mode.

110

LUN Manager operations