Firmware revision mismatch, Mechanism error, Memory is full – HP Photosmart C6280 All-in-One Printer User Manual

Page 151: Scanner failure, Photo tray problem

Advertising
background image

Photo tray cannot disengage

Two-sided printing accessory is missing

Firmware revision mismatch

Cause: The revision number of the HP All-in-One firmware does not match the
revision number of the software.
Solution: To find support and warranty information, go to the HP Web site at

www.hp.com/support

. If prompted, choose your country/region, and then click

Contact HP for information on calling for technical support.

Mechanism error

Cause: The HP All-in-One has a paper jam.
Solution: Clear the paper jam.

For more information, see:

“Clear paper jams” on page 111

Cause: The print head assembly is blocked or stalled.
Solution: Turn the HP All-in-One off and open the ink cartridge door. Remove any
objects that are blocking the print head assembly (including any packing materials),
and then turn the HP All-in-One on again.

Memory is full

Cause: The document you are copying has exceeded the memory of the HP All-in-
One.
Solution: Try making fewer copies.

Scanner failure

Cause: The HP All-in-One is busy or an unknown cause has interrupted your scan.

Solution: Turn off the HP All-in-One and then turn it on again. Restart your
computer and then try to scan again.
If the problem persists, try plugging the power cord directly into a grounded power
outlet rather than a surge protector or power strip. If the problem continues, contact
HP support. Go to

www.hp.com/support

. If prompted, choose your country/region,

and then click Contact HP for information on calling for technical support.

Photo tray problem

Cause: There is not enough paper in the photo tray.
Solution: If the photo tray is empty or there are only a few sheets remaining, load
more paper in the photo tray. If there is paper in the photo tray, remove the paper,

Chapter 14