2 safety measures, 1 general power supply safety measures, 2 reverse power input to rf output connector – Anritsu MG3641A User Manual

Page 32: Caution

Advertising
background image

SECTION 2 PRECAUTION

2-2

To protect circuits from an abnormal rise in the internal temperature, the MG3641A/MG3642A has a built-in

thermal protector. When the thermal protector operates, the MG3641A/MG3642A enters stand-by status (the stby

lamp lights).

If the thermal protector starts operating, check conditions surrounding the device and, after lowering the temperature

sufficiently, reset switch

| on the rear panel. If the thermal protector enters operation repeatedly, the fan may be

broken. In this case, have it repaired.

2.2

Safety Measures

This section explains the safety measures required in any case to prevent the operator from being endangered and

avoid device damage and serious system-down.

2.2.1

General power supply safety measures

CAUTION

Before power-on

: Be sure to ground the MG3641A/MG3642A. If the power is turned on without the

protective grounding, it may result in an electric shock causing death or injury.

Also be sure to check the AC line voltage. Applying an abnormal power exceeding

the determined value to the device may damage the device and cause fire.

During power supply : To maintain the MG3641A/MG3642A, the operator may have to check and adjust the

internal units while opening its cover during power supply. The internal units contain

some high-voltage dangerous parts. If the operator touches them carelessly, it may

result in an electric shock that affects a person's life and injury. For maintenance of

this device, contact qualified service personnel.

2.2.2

Reverse power input to RF output connector

The MG3641A/MG3642A has a reverse power protector in the output unit to protect the internal circuits from a

reverse input overpower. The reverse power protector can protect the following power:

±50 Vdc

• 50 W (Up to 1040 MHz)

• 25 W (1040 to 2080 MHz, MG3642A)

CAUTION

The reverse power protector uses a mechanical switch. If a reverse power is applied frequently, the contact is

consumed. To use this protector, take maximum care not to apply a reverse power. Also never release the

reverse power protector as a reverse power remains applied, or a fault will occur in the reverse power protector.

The impedance of the RF output connector is opened during operation of the reverse power circuit. Be careful

to avoid damage due to a mismatched transmitter, etc.