SECTION 4 OPERATING INSTRUCTIONS

Sweep Auxiliary
Output Connector

MG3641A/MG3642A rear panel

4.10.3 Sweep Auxiliary Outputs

While the signal generator performs sweep, it outputs signals that are synchronized to the sweep through the four

connectors located on the rear panel, as follows:

(1) X Out

Outputs sawtooth waves that are at 0 V at the sweep start point, and at +10 V at the sweep end point.

(2) Z Out

Outputs "H"-level TTL signals while it continues with sweep.

(3) Blanking Out

Outputs "H"-level TTL signals every sweep step, from the time when hardware setting is completed, till the next

step setting begins

(4) Marker Out

Outputs "H"-level TTL signals when the actual sweep matches the marker point which was set in the "Sweep

Parameter" menu.