6 setting the modulation, 1 outline of modulation – Anritsu MG3641A User Manual

Page 58

Advertising
background image

SECTION 4 OPERATING INSTRUCTIONS

4.6

Setting the Modulation

4.6.1

Outline of Modulation

This signal generator provides AM and FM modulation functions. The FM modulation has two systems: FM1 and

FM2, frequency deviation of which can be set independently of each other.

This unit also comes with 5 different modulation signal sources, as shown below, and you can select any one of

them for each type of modulation.

Internal modulation

: Int1 ........ Sine wave of 1 kHz or 400 Hz

Int2 ........ 0.01 Hz to 400 kHz digital synthesizer

Int3 ........ 0.01 Hz to 400 kHz digital synthesizer

External modulation : Ext1 ....... Signal supplied to the Mod Input Ext1 connector

Ext2 ....... Signal supplied to the Mod Input Ext2 connector

The flow of modulation signals is graphically presented below:

Ext1

Int1

Ext2

AF Output

Int2

Int3

Ext1

Ext2

+ −

+ −

+ −

Mod Input

Modulation Source Selection Matrix

1 kHz/400 Hz

sine-wave

oscillator

Internal

modulation source

2

(Option)

Internal

modulation source

3

(Option)

Polarity

switching

Polarity

switching

Polarity

switching

FM1 frequency

deviation setting

FM2 frequency

deviation setting

AM modulation

factor setting

Σ

AF output level setting

FM modulator

AM modulator

Flow of Modulation Signals

Advertising