Ov4.1.1 real time tables – Campbell Scientific CR5000 Measurement and Control Module User Manual

Page 17

Advertising
background image

CR5000 Overview

OV-13

OV4.1.1 Real Time Tables

Table1

Temps

Public

Tref :

23.0234

TCTemp(1) :

19.6243

TCTemp(2) :

19.3429

TCTemp(3) :

21.2003

Flag(1) :

-1.0000

Flag(2) :

0.00000

Flag(3) :

0.00000

Flag(4) :

0.00000

Scaler Manual
Upper: 30.000000
Lower: 20.000000
Display Val

On

Display Max

On

Display Min

On

Graph Type

Roll

30.0

22.35





_____
___ ____
__

20.00

List of Data Tables created by
active program. For Example,

Cursor to desired
Table and press
Enter

TCTemp(3)

:

Tref :

23.0234

TCTemp(1) :

19.6243

TCTemp(2) :

19.3429

TCTemp(3) :

21.2003

Flag(1) :

-1.0000

Flag(2) :

0.00000

Flag(3) :

0.00000

Flag(4) :

0.00000

Fl (3)

TCTemp(3)

2

Public Table values
can be changed.
Cursor to value and
press Enter to edit

value.

Press Graph/ Char
for Graph of
selected field

Press Ins for
Graph Setup

New values are displayed as they
are stored.