Appendix a. cr5000 status table – Campbell Scientific CR5000 Measurement and Control Module User Manual
Page 229
A-1
Appendix A. CR5000 Status Table
The CR5000 status table contains current system operating status information
that can be accessed from the running CR5000 program or monitored by PC
software. There is also a way to view the status information from the
keyboard. Table 1 shows the variables in the status table and a brief
explanation of each follows.
Table 1. CR5000 Status Table
Name
Type
ROMVersion
String
OSVersion
String
OSItem
Float
OSDate
String
StationName
String
ProgName
String
StartTime
Time
Battery
Float
PanelTemp
Float
LithiumBattery
Integer(Boolean)
CPUSignature
Integer
DLDSignature
Integer
ProgSignature
Integer
PC-CardBytesFree
Integer
MemoryFree
Integer
DLDBytesFree
Integer
ProcessTime
Integer
MaxProcTime
Integer
MeasureTime
Integer
SkippedScan
Integer
SlowProcTime
Integer(array)
MaxSlowProcTime
Integer(array)
LastSlowScan
Integer(array)
SkippedSlowScan
Integer(array)
MeasureOps
Integer
WatchdogErrors
Integer
Low12VCount
Integer
StartUpCode
Integer
CommActive
Integer(Boolean)
ProgErrors
Integer
ErrorCalib
Integer
VarOutOfBound
Integer
SkippedRecord
Integer(array)
SecsPerRecord
Integer(array)
SrlNbr
integer
Rev
integer
CalVolts
Float(array)
CalGain
Float(array)