Troubleshooting

205

7" Modero Touch Panels

Troubleshooting Information (Cont.)

Symptom

Solution

I have more that one Modero panel
connected to my System Master
and only one shows up.

Multiple NetLinx Compatible devices (such as Modero panels) can be
associated for use with a single Master. Each Modero panel comes
with a defaulted Device Number value of 10001. When using multiple
panels, it can become very easy to overlook the need to assign
different Device Number values to each panel.

• Press and hold the grey Front Setup Access button for 3 seconds to

open the Setup page.

• Press the Protected Setup button (located on the lower-left of the

panel page), enter 1988 into the on-screen Keypad’s password field,
and press Done when finished.

• Enter a Device Number value for the panel into the Device Number

Keypad. The default is 10001 and the range is from 1 - 32000.

After downloading a panel file or
firmware to a G4 device, the panel
behaves strangely.

Symptoms include:

• Having to repeat the download.

• Inability to make further downloads to the panel. May get "directory"

errors, "graphics hierarchy" errors, etc.… indicating problems with
the Compact Flash.

• Panel will not boot, or gets stuck on "AMX" splash screen.

• Other problems also started after downloading to a new panel or a

panel with a TPD4 file that takes up a considerable amount of the
available Compact Flash.

Cause:

• If the G4 device already contains a large enough file, subsequent

downloads will take up more space than is available and could often
corrupt the Compact Flash. The demo file that typically ships with G4
panels is one such file.

Solution:

• DO NOT download TPD4 files (of large size) over the demo pages, or

any other large TPD4 file.

• First download a small blank one page file to the G4 panel using the

Normal Transfer option to send/download the page. Reboot the
device, then do your regular file or firmware download.

My NXA-BASE/1 Battery Base isn’t
being recognized by the NXT
touch panel.

The battery base CAN NOT be "hot swapped". This swapping
occurs when an NXT panel is currently being powered by a PSN and
then is connected to a battery base containing NXT-BP batteries.
Introducing a new power source onto an existing configuration can
damage the NXA-BASE.

Solution:

If your base is not being recognized by the touch panel but is still pro-
viding power:

• Launch the latest NetLinx Studio.

• Refresh the particular System from within the OnLine Tree tab.

• Identify the NXT panel using the battery base.

• From the Main menu go to Tools > Firmware Transfers > Send to

NetLinx Device.

• Locate and select the 2255_XXX_v2_00 KIT file for the battery base.

• Enter the Device and System values, verify the method of

communication (IP recommended).

• Click Send to reload the new base KIT file onto the NXA-BASE/1.

If this above steps do not cause the base to be recognized by the NXT
touch panel on the Setup page, contact AMX Technical Support for
further assistance.