Configuring Communication

75

7" Modero Touch Panels

2.

Press the Protected Setup button (located on the lower-left of the panel page) to open the Protected
Setup page and display an on-screen keypad.

3.

Enter 1988 into the Keypad’s password field (1988 is the default password).

4.

Press Done when finished.

5.

Press the G4 WebControl button to open the G4 Web Control page (FIG. 72).

6.

Press the Enable/Enabled button until it toggles to Enabled (light blue color).

7.

The Network Interface Select field is read-only and displays the method of communication to the
web. Verify you have selected the proper interface connection as this field does not auto-detect
the connection type being used (see below
).



Wired is used when a direct Ethernet connection is being used for communication to the web.

This is the default setting if either no wireless interface card is detected or if both an Ethernet
and wireless card connection is detected by the panel.



Wireless is used when a wireless card is detected within the internal card slot. This method
provides an indirect communication to the web via a pre-configured Wireless Access Point.

8.

Press the Web Control Name field to open the Web Name keyboard.

9.

From the Web Name keyboard, enter a unique alpha-numeric string to identify this panel. This
information is used by the NetLinx Security Web Server to display on-screen links to the panel. The
on-screen links use the IP Address of the panel and not the name for communication
(FIG. 73).

10.

Press Done after you are finished assigning the alpha-numeric string for the Web Control name.

11.

Press the Web Control Password field to open the Web Password keyboard.

12.

From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4
Authentication session password associated with VNC web access of this panel.

13.

Press Done after you are finished assigning the alpha-numeric string for the Web Control password.

14.

Press the Web Control Port field to open the Web Port Number keypad.

15.

Within the keypad, enter a unique numeric value to be assigned to the port the VNC Web Server is
running on. The default value is 5900.

16.

Press Done when you are finished entering the value. The remaining fields within the G4 Web
Control Settings section of this page are read-only and cannot be altered.

Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.

FIG. 72

G4 Web Control page