Installation

45

7" Modero Touch Panels

The following table lists the pinouts, signals, and pairing associated with the Ethernet connector.

FIG. 44 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.

USB Port: Connecting and Using Input Devices

The CV7 panel can have up to two USB-capable input devices connected for use on its different
firmware and TPD4 panel pages. These input devices can consist of a keyboard or mouse.

1.

Insert the input device USB connectors into the appropriate USB connector on the panel.

2.

Press the on-screen Reboot button from the Protected Setup page to save any changes and restart
the panel.

3.

After the panel splash-screen disappears:



If a USB mouse has been connected, a mouse cursor appears on the panel screen and its
location corresponds to the mouse cursor position sent by the external USB mouse.



If a USB keyboard has been connected, only on-screen keyboards and keypads will reflect any

external keystrokes sent from the external USB keyboard.

Ethernet RJ-45 Pinouts and Signals

Pin

Signals

Connections Pairing

Color

1

TX +

1 --------- 1

1 --------- 2

Orange-White

2

TX -

2 --------- 2

Orange

3

RX +

3 --------- 3

3 --------- 6

Green-White

4

no connection

4 --------- 4

Blue

5

no connection

5 --------- 5

4 --------- 5

Blue-White

6

RX -

6 --------- 6

Green

7

no connection

7 --------- 7

7 --------- 8

Brown-White

8

no connection

8 --------- 8

Brown

FIG. 44

RJ-45 wiring diagram

USB-connected input devices are not detected and recognized by the panel until
power is cycled to the unit.
A mini-USB connection is only detected after it is installed onto an active
panel. Connection to a previously powered panel, allows the PC to detect the
panel and assign an appropriate USB driver.